UGC Approved Journal no 63975(19)

ISSN: 2349-5162 | ESTD Year : 2014
Call for Paper
Volume 11 | Issue 4 | April 2024

JETIREXPLORE- Search Thousands of research papers



WhatsApp Contact
Click Here

Published in:

Volume 9 Issue 5
May-2022
eISSN: 2349-5162

UGC and ISSN approved 7.95 impact factor UGC Approved Journal no 63975

7.95 impact factor calculated by Google scholar

Unique Identifier

Published Paper ID:
JETIR2205B70


Registration ID:
403411

Page Number

k523-k530

Share This Article


Jetir RMS

Title

PERFORMANCE BASED ANALYSIS OF G+10 MUTISTOREYED BUILDING WITH TRANSFER GIRDERS

Abstract

A Floating Column should be an upward part beginning from the Service floor level. It is not attached to any type of Footing on the ground. The term drifting segment is likewise an upward component that closes (as a result of the building plan) at its lower level (end Level) and lays on a shaft which is an even part. The bars thus 'move the heap to different sections beneath it. Such sections were where the heap was considered as a point load. Hypothetically such constructions can be investigated and planned. Practically speaking, the genuine sections underneath the end level [usually the brace level] are not developed with care and are more obligated to disappointment. In this Study I have planned a Service Floor of 3m saved after 6m Parking Height, I examined G+10 Multistory 3 Star Hotel utilizing ETABS, SAFE, and RCDC. What's more, attempted to show these exchange supports are fit to oppose the different tremor powers by unique Analysis. Move shaft is a level construction that moves weighty gravity loads from the above underlying components to the underneath structures. These are shaft components that are essentially utilized in the plan of tall structure structures. They are intended to take up a load more than whatever an ordinary bar is intended for. Move 'radiates are expected where segment areas are changing, and to move the powers from section above to segment beneath. To plan the exchange shafts (or supports), simply consider the point loads at the places where the segments are halting. This point burden will really be equivalent to the greatness of the segment response.

Key Words

Service Floor, Transfer Girder Beam, Floating Column, ETABS.

Cite This Article

"PERFORMANCE BASED ANALYSIS OF G+10 MUTISTOREYED BUILDING WITH TRANSFER GIRDERS ", International Journal of Emerging Technologies and Innovative Research (www.jetir.org), ISSN:2349-5162, Vol.9, Issue 5, page no.k523-k530, May-2022, Available :http://www.jetir.org/papers/JETIR2205B70.pdf

ISSN


2349-5162 | Impact Factor 7.95 Calculate by Google Scholar

An International Scholarly Open Access Journal, Peer-Reviewed, Refereed Journal Impact Factor 7.95 Calculate by Google Scholar and Semantic Scholar | AI-Powered Research Tool, Multidisciplinary, Monthly, Multilanguage Journal Indexing in All Major Database & Metadata, Citation Generator

Cite This Article

"PERFORMANCE BASED ANALYSIS OF G+10 MUTISTOREYED BUILDING WITH TRANSFER GIRDERS ", International Journal of Emerging Technologies and Innovative Research (www.jetir.org | UGC and issn Approved), ISSN:2349-5162, Vol.9, Issue 5, page no. ppk523-k530, May-2022, Available at : http://www.jetir.org/papers/JETIR2205B70.pdf

Publication Details

Published Paper ID: JETIR2205B70
Registration ID: 403411
Published In: Volume 9 | Issue 5 | Year May-2022
DOI (Digital Object Identifier):
Page No: k523-k530
Country: Ahmednnagar, Maharashtra, India .
Area: Engineering
ISSN Number: 2349-5162
Publisher: IJ Publication


Preview This Article


Downlaod

Click here for Article Preview

Download PDF

Downloads

000269

Print This Page

Current Call For Paper

Jetir RMS