UGC Approved Journal no 63975(19)

ISSN: 2349-5162 | ESTD Year : 2014
Call for Paper
Volume 11 | Issue 4 | April 2024

JETIREXPLORE- Search Thousands of research papers



WhatsApp Contact
Click Here

Published in:

Volume 9 Issue 8
August-2022
eISSN: 2349-5162

UGC and ISSN approved 7.95 impact factor UGC Approved Journal no 63975

7.95 impact factor calculated by Google scholar

Unique Identifier

Published Paper ID:
JETIR2208494


Registration ID:
501602

Page Number

e766-e774

Share This Article


Jetir RMS

Title

DEVELOPMENT AND VALIDATION OF RP -HPLC METHOD FOR SIMULTANEOUS ESTIMATION OF BISOPROLOL FUMARATE AND TELMISARTAN IN BULK AND PHARMACEUTICAL FORMULATION

Abstract

New, simple and sensitive RP-HPLC method was developed for simultaneous estimation of Bisoprolol Fumarate and Telmisartan in bulk and tablet formulation. The present study was undertaken to develop and validate an accurate, robust, precise and cost – effective RP-HPLC method for the simultaneous estimation of Bisoprolol fumarate and Telmisartan in bulk and tablet pharmaceutical formulation. Separation was achieved on C8 Column (150mmx4.6mm,5µm) using Ammonium formate, Acetonitrile :Methanol (50:50 v/v) as a mobile phase with flow rate of 1.0ml/min. The detection carried out at wavelength 231 nm. The retention times of Bisoprolol fumarate and Telmisartan were found that 6.7 min and 9.0 min respectively. The method was validated in terms of linearity, precision, Robustness, calibration as per ICH guidelines. linearity was carried out by using concentration range 5-25 µg.mL-1 for Bisoprolol fumarate and 40-200 µg.mL-1 for Telmisartan. The method shows linearity in the mentioned concentration having correlation coefficient R2 0.999 and 0.999respectively. The mean recoveries of bisoprolol fumarate and telmisartan were found to be 99-101% respectively. The %RSD of the Bisoprolol fumarate and Telmisartan were found to be 0.38-0.54 and 0.01-0.51 respectively. The development RP-HPLC method was found to be highly specific. The method could be applicable for routine determination in bulk drug as well as dosage formulation containing Bisoprolol and Telmisartan combination.

Key Words

KEY WORDS : RP-HPLC; Bisoprolol fumarate; Telmisartan; Validation; Simultaneous estimation; etc

Cite This Article

"DEVELOPMENT AND VALIDATION OF RP -HPLC METHOD FOR SIMULTANEOUS ESTIMATION OF BISOPROLOL FUMARATE AND TELMISARTAN IN BULK AND PHARMACEUTICAL FORMULATION", International Journal of Emerging Technologies and Innovative Research (www.jetir.org), ISSN:2349-5162, Vol.9, Issue 8, page no.e766-e774, August-2022, Available :http://www.jetir.org/papers/JETIR2208494.pdf

ISSN


2349-5162 | Impact Factor 7.95 Calculate by Google Scholar

An International Scholarly Open Access Journal, Peer-Reviewed, Refereed Journal Impact Factor 7.95 Calculate by Google Scholar and Semantic Scholar | AI-Powered Research Tool, Multidisciplinary, Monthly, Multilanguage Journal Indexing in All Major Database & Metadata, Citation Generator

Cite This Article

"DEVELOPMENT AND VALIDATION OF RP -HPLC METHOD FOR SIMULTANEOUS ESTIMATION OF BISOPROLOL FUMARATE AND TELMISARTAN IN BULK AND PHARMACEUTICAL FORMULATION", International Journal of Emerging Technologies and Innovative Research (www.jetir.org | UGC and issn Approved), ISSN:2349-5162, Vol.9, Issue 8, page no. ppe766-e774, August-2022, Available at : http://www.jetir.org/papers/JETIR2208494.pdf

Publication Details

Published Paper ID: JETIR2208494
Registration ID: 501602
Published In: Volume 9 | Issue 8 | Year August-2022
DOI (Digital Object Identifier):
Page No: e766-e774
Country: Amravati, MAHARASHTRA, India .
Area: Pharmacy
ISSN Number: 2349-5162
Publisher: IJ Publication


Preview This Article


Downlaod

Click here for Article Preview

Download PDF

Downloads