UGC Approved Journal no 63975(19)

ISSN: 2349-5162 | ESTD Year : 2014
Call for Paper
Volume 11 | Issue 4 | April 2024

JETIREXPLORE- Search Thousands of research papers



WhatsApp Contact
Click Here

Published in:

Volume 9 Issue 10
October-2022
eISSN: 2349-5162

UGC and ISSN approved 7.95 impact factor UGC Approved Journal no 63975

7.95 impact factor calculated by Google scholar

Unique Identifier

Published Paper ID:
JETIR2210249


Registration ID:
503602

Page Number

c393-c396

Share This Article


Jetir RMS

Title

A REVIEW PAPER ON INTERFERENCE EFFECT BETWEEN TALL BUILDINGS WITH SQUARE CROSS-SECTIONS UNDER WIND LOADS

Abstract

Wind load on tall square shaped building for wind incidence angle of 0° in isolated condition can be easily estimated by using available code of practice. However, wind tunnel tests are required for various wind incidence angles and to investigate the influence of the presence of an interfering building on the major building. In this study, 10 storeys building with square cross section and having 4 bays in both the direction is analyzed for different wind incident angles (0°, 30°, 60°) by using the values of pressure coefficient at different nodes for determining various parameters like deflection, bending moment, storey drift and maximum absolute stress. Furthermore, interference effect by varying the distance (y = 0, 0.5b, b, 1.5b, 2b) between upstream interfering building and principal building is also investigated. This analysis is performed by using Standard package STADD.Pro V8i software and the wind pressure coefficient for different angles of wind incidence and for various configuration of interference is obtained by conducting wind tunnel test and the results are recorded in form of pressure contours. Then using these pressure contours it is concluded that for 0° wind incidence in isolated condition deflection observed from wind tunnel studies and from Indian standard codes are similar. Later, it is found out that from all the available location of shear walls, optimum location is when shear wall is present at central core of building

Key Words

Gust Effect, Wind Effect

Cite This Article

"A REVIEW PAPER ON INTERFERENCE EFFECT BETWEEN TALL BUILDINGS WITH SQUARE CROSS-SECTIONS UNDER WIND LOADS", International Journal of Emerging Technologies and Innovative Research (www.jetir.org), ISSN:2349-5162, Vol.9, Issue 10, page no.c393-c396, October-2022, Available :http://www.jetir.org/papers/JETIR2210249.pdf

ISSN


2349-5162 | Impact Factor 7.95 Calculate by Google Scholar

An International Scholarly Open Access Journal, Peer-Reviewed, Refereed Journal Impact Factor 7.95 Calculate by Google Scholar and Semantic Scholar | AI-Powered Research Tool, Multidisciplinary, Monthly, Multilanguage Journal Indexing in All Major Database & Metadata, Citation Generator

Cite This Article

"A REVIEW PAPER ON INTERFERENCE EFFECT BETWEEN TALL BUILDINGS WITH SQUARE CROSS-SECTIONS UNDER WIND LOADS", International Journal of Emerging Technologies and Innovative Research (www.jetir.org | UGC and issn Approved), ISSN:2349-5162, Vol.9, Issue 10, page no. ppc393-c396, October-2022, Available at : http://www.jetir.org/papers/JETIR2210249.pdf

Publication Details

Published Paper ID: JETIR2210249
Registration ID: 503602
Published In: Volume 9 | Issue 10 | Year October-2022
DOI (Digital Object Identifier):
Page No: c393-c396
Country: CHANDIGARH, CHANDIGARH, India .
Area: Engineering
ISSN Number: 2349-5162
Publisher: IJ Publication


Preview This Article


Downlaod

Click here for Article Preview

Download PDF

Downloads

000160

Print This Page

Current Call For Paper

Jetir RMS