Weighted Least-Square Phasor Measurements with State Estimation in Power System

Abstract

Power System State Estimation, being a process to estimate voltage angle as well as the magnitude state for every bus of system of the power that is based on measurements which have been carried at only buses. The devices for the measurement of the earlier days, have only been able to give quantity measured magnitude. Nevertheless, a measurement device with the efficiency known as the Phasor-Measurement-Unit (PMU) which is helpful for the measurement of the phasor of voltage (both magnitude a well as the angle) of a bus at which it’s placed as well as the phasors of current of directly connected lines are being used. Since PMUs are very costly, one cannot use PMU measurements only to estimate the state of a power system. Hence, phasor measurements are used as an additional measurement with traditional measurements to estimate the state of a power system. In this paper, use of PMU measurements to estimate the state of a power system has been explained and a MATLAB program has been coded as well as a simulation has been carried out on IEEE-14 bus and IEEE-30 bus systems for verification of the method. The method uses, a distinct estimator model of the linear state to use the estimate for the state from the WLS, as well as the current measurements and the PMU voltage through the post-processing. First the model estimates the state in polar coordinates using WLS state estimation method from conventional measurements. Then this state, with PMU measurements, both expressed in rectangular coordinates, is used to estimate the final state of the system.

Key Words

Phasor Measurement Unit- PMU, Weight Least Square- WLS, State Estimator

Cite This Article

"Weighted Least-Square Phasor Measurements with State Estimation in Power System", International Journal of Emerging Technologies and Innovative Research (www.jetir.org), ISSN:2349-5162, Vol.9, Issue 12, page no.c247-c251, December-2022, Available :http://www.jetir.org/papers/JETIR2212235.pdf

ISSN


2349-5162 | Impact Factor 7.95 Calculate by Google Scholar

An International Scholarly Open Access Journal, Peer-Reviewed, Refereed Journal Impact Factor 7.95 Calculate by Google Scholar and Semantic Scholar | AI-Powered Research Tool, Multidisciplinary, Monthly, Multilanguage Journal Indexing in All Major Database & Metadata, Citation Generator

Cite This Article

"Weighted Least-Square Phasor Measurements with State Estimation in Power System", International Journal of Emerging Technologies and Innovative Research (www.jetir.org | UGC and issn Approved), ISSN:2349-5162, Vol.9, Issue 12, page no. ppc247-c251, December-2022, Available at : http://www.jetir.org/papers/JETIR2212235.pdf

Publication Details

Published Paper ID: JETIR2212235
Registration ID: 505750
Published In: Volume 9 | Issue 12 | Year December-2022
DOI (Digital Object Identifier):
Page No: c247-c251
Country: Greater Noida, Uttar Pradesh, India .
Area: Engineering
ISSN Number: 2349-5162
Publisher: IJ Publication


Preview This Article


Downlaod

Click here for Article Preview

Download PDF

Downloads

000329

Print This Page

Current Call For Paper

Jetir RMS