Experimental Analysis on Mud Tube Air Conditioning Camper with Existing

Abstract

Day to day due to energy crisis and increasing demand along with its harmful effect to atmosphere, there is serious need of energy saving in air cooling systems. Although, evaporative cooling is well known technique from long time providing best results with applicability in number of areas such as, in residential, commercial, agricultural, and institutional buildings to industrial applications. However, direct evaporation systems lead to increased humidity causing a number of ailments like whereas indirect systems suffer from loss in efficiency. This project test setup is development for performance and evaluation of a mud tube air Conditioning system. This system may also be used as an enthalpy exchanger depending upon the characteristics of prevailing air. Water in the tank is made to drip at a controlled rate into the porous mud tubes that allow capillary action. A thin layer of water formed on the surface of mud tubes is used to exchange sensible and latent heat with the current of outdoor air This system is highly efficient can save up to 20-30% of high-grade electrical energy and 50%of the water in comparison to it evaporative air cooler. As well as the compared with conventional cooling 7-9 degree temperature reduction is obtained. Fresh and moisture free air is obtained.

Key Words

Cite This Article

"Experimental Analysis on Mud Tube Air Conditioning Camper with Existing", International Journal of Emerging Technologies and Innovative Research (www.jetir.org), ISSN:2349-5162, Vol.10, Issue 3, page no.a149-a155, March-2023, Available :http://www.jetir.org/papers/JETIR2303019.pdf

ISSN


2349-5162 | Impact Factor 7.95 Calculate by Google Scholar

An International Scholarly Open Access Journal, Peer-Reviewed, Refereed Journal Impact Factor 7.95 Calculate by Google Scholar and Semantic Scholar | AI-Powered Research Tool, Multidisciplinary, Monthly, Multilanguage Journal Indexing in All Major Database & Metadata, Citation Generator

Cite This Article

"Experimental Analysis on Mud Tube Air Conditioning Camper with Existing", International Journal of Emerging Technologies and Innovative Research (www.jetir.org | UGC and issn Approved), ISSN:2349-5162, Vol.10, Issue 3, page no. ppa149-a155, March-2023, Available at : http://www.jetir.org/papers/JETIR2303019.pdf

Publication Details

Published Paper ID: JETIR2303019
Registration ID: 508913
Published In: Volume 10 | Issue 3 | Year March-2023
DOI (Digital Object Identifier):
Page No: a149-a155
Country: Nagpur, Maharashtra, India .
Area: Engineering
ISSN Number: 2349-5162
Publisher: IJ Publication


Preview This Article


Downlaod

Click here for Article Preview

Download PDF

Downloads

000326

Print This Page

Current Call For Paper

Jetir RMS