UGC Approved Journal no 63975(19)
New UGC Peer-Reviewed Rules

ISSN: 2349-5162 | ESTD Year : 2014
Volume 13 | Issue 4 | April 2026

JETIREXPLORE- Search Thousands of research papers



WhatsApp Contact
Click Here

Published in:

Volume 10 Issue 4
April-2023
eISSN: 2349-5162

UGC and ISSN approved 7.95 impact factor UGC Approved Journal no 63975

7.95 impact factor calculated by Google scholar

Unique Identifier

Published Paper ID:
JETIR2304862


Registration ID:
513229

Page Number

g424-g431

Share This Article


Jetir RMS

Title

Digital relay scheme for transformer protection

Abstract

Transformers are one of the most crucial equipment in a power system. So it should be protected from various external conditions of faults and malfunctioning. The protective system is developed around it should able distinguish faults and non fault conditions. Differential protection based systems are used by transformers for its protection. Various techniques based on differential protection are proposed in the literature. But these techniques does not provide better performance. This paper proposes a novel approach of differential protection based on covariance and CUSUM. This technique is used to distinguish between fault and non-fault conditions. This suggested algorithm has been evaluated under a variety of failure scenarios, including: (where no Fault condition like High Inrush currents, Current Transformer saturation ). Fault state, such as (winding turns faults, 3 phase fault). This method is developed in MATLAB and outcomes shows that proposed technique has produced a better response then existing ones. allowing the fault to be detected in just milliseconds after its incidence.

Key Words

Differential protection, covariance and CUSUM

Cite This Article

"Digital relay scheme for transformer protection ", International Journal of Emerging Technologies and Innovative Research (www.jetir.org), ISSN:2349-5162, Vol.10, Issue 4, page no.g424-g431, April-2023, Available :http://www.jetir.org/papers/JETIR2304862.pdf

ISSN


2349-5162 | Impact Factor 7.95 Calculate by Google Scholar

An International Scholarly Open Access Journal, Peer-Reviewed, Refereed Journal Impact Factor 7.95 Calculate by Google Scholar and Semantic Scholar | AI-Powered Research Tool, Multidisciplinary, Monthly, Multilanguage Journal Indexing in All Major Database & Metadata, Citation Generator

Cite This Article

"Digital relay scheme for transformer protection ", International Journal of Emerging Technologies and Innovative Research (www.jetir.org | UGC and issn Approved), ISSN:2349-5162, Vol.10, Issue 4, page no. ppg424-g431, April-2023, Available at : http://www.jetir.org/papers/JETIR2304862.pdf

Publication Details

Published Paper ID: JETIR2304862
Registration ID: 513229
Published In: Volume 10 | Issue 4 | Year April-2023
DOI (Digital Object Identifier):
Page No: g424-g431
Country: Visakhapatnam, Andhra Pradesh, India .
Area: Engineering
ISSN Number: 2349-5162
Publisher: IJ Publication


Preview This Article


Downlaod

Click here for Article Preview

Download PDF

Downloads

000164

Print This Page

Current Call For Paper

Jetir RMS