UGC Approved Journal no 63975(19)

ISSN: 2349-5162 | ESTD Year : 2014
Call for Paper
Volume 11 | Issue 4 | April 2024

JETIREXPLORE- Search Thousands of research papers



WhatsApp Contact
Click Here

Published in:

Volume 10 Issue 4
April-2023
eISSN: 2349-5162

UGC and ISSN approved 7.95 impact factor UGC Approved Journal no 63975

7.95 impact factor calculated by Google scholar

Unique Identifier

Published Paper ID:
JETIR2304B73


Registration ID:
513892

Page Number

l509-l517

Share This Article


Jetir RMS

Title

“THERMAL MODELING OF TWO STAGE VAPOUR COMPRESSION CASCADE REFRIGERATION SYSTEM USING R41/R290 & R41/R404A”

Abstract

The choice of refrigerants for the High Temperature Circuit and the Low Temperature Circuit is the most important part of the design of a Cascade Refrigeration System (CRS). My research project's goal is to look at two different Cascade Refrigeration Systems that use two different sets of refrigerant, R41/R290 and R41/R404A. Thermodynamic analysis is done on the performance of Cascade Refrigeration System with R41/R290 refrigerant pair and R41/R404A refrigerant pair. This is done with the help of a mathematical model. Mathematical modeling is done with the help of the EES-Engineering Equation Solver software. Under different operating conditions like TEVA, TCON, and TCASLTC, the performance of a Cascade Refrigeration System was looked at in terms of Coefficient of Performance, total exergy destruction, total work and exergetic efficiency. The results indicate that the Coefficient of Performance of the refrigerant pair R41/R290 used in a Cascade Refrigeration System is higher than the Coefficient of Performance of the refrigerant pair R41/R404A used in the same operating conditions.

Key Words

EES, CRS, Coefficient of Performance, Thermal Modeling

Cite This Article

"“THERMAL MODELING OF TWO STAGE VAPOUR COMPRESSION CASCADE REFRIGERATION SYSTEM USING R41/R290 & R41/R404A”", International Journal of Emerging Technologies and Innovative Research (www.jetir.org), ISSN:2349-5162, Vol.10, Issue 4, page no.l509-l517, April-2023, Available :http://www.jetir.org/papers/JETIR2304B73.pdf

ISSN


2349-5162 | Impact Factor 7.95 Calculate by Google Scholar

An International Scholarly Open Access Journal, Peer-Reviewed, Refereed Journal Impact Factor 7.95 Calculate by Google Scholar and Semantic Scholar | AI-Powered Research Tool, Multidisciplinary, Monthly, Multilanguage Journal Indexing in All Major Database & Metadata, Citation Generator

Cite This Article

"“THERMAL MODELING OF TWO STAGE VAPOUR COMPRESSION CASCADE REFRIGERATION SYSTEM USING R41/R290 & R41/R404A”", International Journal of Emerging Technologies and Innovative Research (www.jetir.org | UGC and issn Approved), ISSN:2349-5162, Vol.10, Issue 4, page no. ppl509-l517, April-2023, Available at : http://www.jetir.org/papers/JETIR2304B73.pdf

Publication Details

Published Paper ID: JETIR2304B73
Registration ID: 513892
Published In: Volume 10 | Issue 4 | Year April-2023
DOI (Digital Object Identifier):
Page No: l509-l517
Country: bhopal, m.p, India .
Area: Engineering
ISSN Number: 2349-5162
Publisher: IJ Publication


Preview This Article


Downlaod

Click here for Article Preview

Download PDF

Downloads

000102

Print This Page

Current Call For Paper

Jetir RMS