Title

AN VITRO STENT FOR POST ENDOVASCULAR ANEURYSM IMPROVEMENT

Abstract

Endovascular aneurysm repair (EVAR) is an established and reliable surgical treatment of abdominal aortic aneurysm (AAA), where a covered stent is implanted to prevent blood flow in the aneurysm sac. Although current EVAR is an effective technique, it requires long-term monitoring for the post-operative complications (e.g., endo leak, stent occlusion), which usually requires expensive radiologic imaging techniques such as ultra sonography , computed tomography (CT), or magnetic resonance imaging(MRI). In this paper, we present an accessible and continuous post-EVAR surveillance scheme by developing a smart stent that features ultrasonic powering, blood flow sensing, and integrated wireless electronics. As the body of the smart stent, a piezoelectric membrane with a custom pore architecture is utilized. The benefits of the embedded pore architectures include the expansion and contraction to comply with a minimally invasive procedure and enhanced ultrasonic powering and sensing capability. The smart stent is able to expand up to112% in diameter when stretched due to the negative Poisson's ratio. The ultrasound generates 0.23 mW of electrical power, which can sufficiently operate a low power wireless electronics. A comprehensive operation of the smart stent is demonstrated in vitro. The integrated flow sensor can measure blood flow ranging between 30 mL /min to 980 mL/min with an average sensitivity of 0.11 mV/mL/min. The wireless electronics transmit and receive such blood flow rate data by modulating the carrier frequency from 81 to 88 MHz from1maway. The developed smart stent prototype is the first step towards minimizing post-EVAR complications by providing early and frequent access to diagnostic information to patients and physicians.

Key Words

biomedical telemetry, ultrasonic transducers, sensors ,implantable biomedical devices, endovascular aneurysm repair, stent.

Cite This Article

"AN VITRO STENT FOR POST ENDOVASCULAR ANEURYSM IMPROVEMENT", International Journal of Emerging Technologies and Innovative Research (www.jetir.org), ISSN:2349-5162, Vol.10, Issue 5, page no.b700-b707, May-2023, Available :http://www.jetir.org/papers/JETIR2305192.pdf

ISSN


2349-5162 | Impact Factor 7.95 Calculate by Google Scholar

An International Scholarly Open Access Journal, Peer-Reviewed, Refereed Journal Impact Factor 7.95 Calculate by Google Scholar and Semantic Scholar | AI-Powered Research Tool, Multidisciplinary, Monthly, Multilanguage Journal Indexing in All Major Database & Metadata, Citation Generator

Cite This Article

"AN VITRO STENT FOR POST ENDOVASCULAR ANEURYSM IMPROVEMENT", International Journal of Emerging Technologies and Innovative Research (www.jetir.org | UGC and issn Approved), ISSN:2349-5162, Vol.10, Issue 5, page no. ppb700-b707, May-2023, Available at : http://www.jetir.org/papers/JETIR2305192.pdf

Publication Details

Published Paper ID: JETIR2305192
Registration ID: 515006
Published In: Volume 10 | Issue 5 | Year May-2023
DOI (Digital Object Identifier):
Page No: b700-b707
Country: Namakkal, TAMILNADU, India .
Area: Engineering
ISSN Number: 2349-5162
Publisher: IJ Publication


Preview This Article


Downlaod

Click here for Article Preview

Download PDF

Downloads

000240

Print This Page

Current Call For Paper

Jetir RMS