UGC Approved Journal no 63975(19)

ISSN: 2349-5162 | ESTD Year : 2014
Call for Paper
Volume 11 | Issue 5 | May 2024

JETIREXPLORE- Search Thousands of research papers



WhatsApp Contact
Click Here

Published in:

Volume 10 Issue 7
July-2023
eISSN: 2349-5162

UGC and ISSN approved 7.95 impact factor UGC Approved Journal no 63975

7.95 impact factor calculated by Google scholar

Unique Identifier

Published Paper ID:
JETIR2307982


Registration ID:
522605

Page Number

j662-j669

Share This Article


Jetir RMS

Title

The Role Of Facts Controllers In Enhancing Voltage Stability Of Grid-Connected Wind Farms During Balanced Three Phase Fault

Abstract

To solve voltage stability difficulties in grid-connected wind power systems, this research provides a collaborative control technique that employs Thyristor Controlled Series Compensator (TCSC) and Static Synchronous Compensator (STATCOM). The suggested strategy, which incorporates a dual closed-loop feedback control approach of STATCOM and TCSC, ensures that the wind power grid-connected system maintains sufficient reactive power for consistent and reliable operation. MATLAB/Simulink is used to create the simulation model of the wind power grid-connected system. The results of waveform analysis and comparison with TCSC-only, STATCOM-only, and TCSC-STATCOM situations show that cooperative control of TCSC and STATCOM allows for quick and efficient restoration of bus voltage at the network connection point. Wind farms function admirably after a fault, improving the voltage stability of grid-connected equipment and increasing low-voltage throughput capacity. When compared to separate implementations of TCSC or STATCOM, synergistic control of TCSC and STATCOM produces superior outcomes.

Key Words

Grid, wind farm, voltage stability, TCSC, STATCOM , MATLAB/Simulink.

Cite This Article

"The Role Of Facts Controllers In Enhancing Voltage Stability Of Grid-Connected Wind Farms During Balanced Three Phase Fault", International Journal of Emerging Technologies and Innovative Research (www.jetir.org), ISSN:2349-5162, Vol.10, Issue 7, page no.j662-j669, July-2023, Available :http://www.jetir.org/papers/JETIR2307982.pdf

ISSN


2349-5162 | Impact Factor 7.95 Calculate by Google Scholar

An International Scholarly Open Access Journal, Peer-Reviewed, Refereed Journal Impact Factor 7.95 Calculate by Google Scholar and Semantic Scholar | AI-Powered Research Tool, Multidisciplinary, Monthly, Multilanguage Journal Indexing in All Major Database & Metadata, Citation Generator

Cite This Article

"The Role Of Facts Controllers In Enhancing Voltage Stability Of Grid-Connected Wind Farms During Balanced Three Phase Fault", International Journal of Emerging Technologies and Innovative Research (www.jetir.org | UGC and issn Approved), ISSN:2349-5162, Vol.10, Issue 7, page no. ppj662-j669, July-2023, Available at : http://www.jetir.org/papers/JETIR2307982.pdf

Publication Details

Published Paper ID: JETIR2307982
Registration ID: 522605
Published In: Volume 10 | Issue 7 | Year July-2023
DOI (Digital Object Identifier): http://doi.one/10.1729/Journal.35565
Page No: j662-j669
Country: Meerut, Uttar Pradesh, India .
Area: Engineering
ISSN Number: 2349-5162
Publisher: IJ Publication


Preview This Article


Downlaod

Click here for Article Preview

Download PDF

Downloads

000141

Print This Page

Current Call For Paper

Jetir RMS