Title

CLINICAL APPLICATIONS AND TECHNICAL IMAGES OF HOUNSFIELD UNITS IN CT SCAN

Abstract

This study gives a comprehensive overview of the subject, covering its background, modalities, number of CT scans, Hounsfield units, and scale in relation to specific applications. Currently, computed tomography (CT) has emerged as a groundbreaking technique in the field of medical imaging. In addition to being referred to as the Hounsfield unit, the numerical picture of a pixel is also known as the CT number. The viewpoint that lies behind the quality of the image and the reconstruction of the image in the form of grayscale. The abbreviation for this scale is the HU level. In recognition of Sir Godfrey Newbold Hounsfield, the scale was given the name "Hounsfield Unit." The value of the gray shade is represented by this scale according to the attenuation. Because it assists in determining the degree of radiation intensity decrease and, as a result, provides a specific numerical value in each pixel, attenuation plays a significant part in the process. Information on the HU value may be obtained by establishing a region of interest (ROI) on a specific slice or segment of an image. This information is helpful in determining the relevance of the HU value in terms of detection, assessment, therapy, and diagnosis. The return on investment (ROI), which is taken into consideration and utilized in post-processing approach, provides HU value immediately following its placement, which is not less than Artificial Intelligence (AI).

Key Words

Attenuation , HU scale , Hounsfield Unit , Region of Interest ( ROI )

Cite This Article

"CLINICAL APPLICATIONS AND TECHNICAL IMAGES OF HOUNSFIELD UNITS IN CT SCAN", International Journal of Emerging Technologies and Innovative Research (www.jetir.org), ISSN:2349-5162, Vol.11, Issue 7, page no.h515-h521, July-2024, Available :http://www.jetir.org/papers/JETIR2407762.pdf

ISSN


2349-5162 | Impact Factor 7.95 Calculate by Google Scholar

An International Scholarly Open Access Journal, Peer-Reviewed, Refereed Journal Impact Factor 7.95 Calculate by Google Scholar and Semantic Scholar | AI-Powered Research Tool, Multidisciplinary, Monthly, Multilanguage Journal Indexing in All Major Database & Metadata, Citation Generator

Cite This Article

"CLINICAL APPLICATIONS AND TECHNICAL IMAGES OF HOUNSFIELD UNITS IN CT SCAN", International Journal of Emerging Technologies and Innovative Research (www.jetir.org | UGC and issn Approved), ISSN:2349-5162, Vol.11, Issue 7, page no. pph515-h521, July-2024, Available at : http://www.jetir.org/papers/JETIR2407762.pdf

Publication Details

Published Paper ID: JETIR2407762
Registration ID: 545865
Published In: Volume 11 | Issue 7 | Year July-2024
DOI (Digital Object Identifier): http://doi.one/10.1729/Journal.40796
Page No: h515-h521
Country: VARANASI , UTTAR PRADESH, India .
Area: Science & Technology
ISSN Number: 2349-5162
Publisher: IJ Publication


Preview This Article


Downlaod

Click here for Article Preview

Download PDF

Downloads

000414

Print This Page

Current Call For Paper

Jetir RMS