UGC Approved Journal no 63975(19)
New UGC Peer-Reviewed Rules

ISSN: 2349-5162 | ESTD Year : 2014
Volume 12 | Issue 10 | October 2025

JETIREXPLORE- Search Thousands of research papers



WhatsApp Contact
Click Here

Published in:

Volume 12 Issue 5
May-2025
eISSN: 2349-5162

UGC and ISSN approved 7.95 impact factor UGC Approved Journal no 63975

7.95 impact factor calculated by Google scholar

Unique Identifier

Published Paper ID:
JETIR2505578


Registration ID:
562130

Page Number

e906-e916

Share This Article


Jetir RMS

Title

FORCED CONVECTION HEAT TRANSFER BY USING CLOCKWISE ARRANGEMENT OF BIPARTITION

Abstract

Several decades have been spent on methods to improve the transfer of heat through compound, passive, and active heat augmentation. The present research uses air as the working fluid and non-metallic i.e. Bakelite flow divider type inserts as part of a passive heat transfer augmentation technique. This paper presents an original experimental study on heat transfer enhancement by using arrangement of 4-4 45 degree’s & 90 degree’s clockwise insert. This study investigates the performance of a plain tube with a 90 degree’s insert & 45 degree’s clockwise bipartition insert focusing on the changes in Nusselt number, Reynold number and heat transfer coefficient through experimental methods. Through this experiment comparing the result of turbulent flow without insert, with 4-4 45 degree’s & 90 degree’s clockwise bipartition insert. The experimental setup involved systematically varying Reynolds numbers from range of 5000 to 23000 and heat input varied from 50 V ,75 V, 100V.Through in this study it is found that Nusselt number and heat transfer coefficient changes according to voltage. For 50 V, Nusselt number and heat transfer coefficient with 4-4 45 degree’s & 90 degree’s clockwise bipartition insert is 106% more than without insert. For 75 V, Nusselt number and heat transfer coefficient with 4-4 45 degree’s & 90 degree’s clockwise bipartition insert is 87% more than without insert. For 100 V, Nusselt number and heat transfer coefficient with 4-4 45 degree’s & 90 degree’s clockwise bipartition insert, is 102% more than without insert. So overall experiment shows that forced convection heat transfer using 4-4 45 degree’s & 90 degree’s clockwise bipartition insert gives higher Reynold Number, heat transfer coefficient and Nusselt number effectively

Key Words

Forced Convection, Nusselt Number, Reynolds Number, Flow Divider Perforated Insert, Heat Augmentation

Cite This Article

"FORCED CONVECTION HEAT TRANSFER BY USING CLOCKWISE ARRANGEMENT OF BIPARTITION", International Journal of Emerging Technologies and Innovative Research (www.jetir.org), ISSN:2349-5162, Vol.12, Issue 5, page no.e906-e916, May-2025, Available :http://www.jetir.org/papers/JETIR2505578.pdf

ISSN


2349-5162 | Impact Factor 7.95 Calculate by Google Scholar

An International Scholarly Open Access Journal, Peer-Reviewed, Refereed Journal Impact Factor 7.95 Calculate by Google Scholar and Semantic Scholar | AI-Powered Research Tool, Multidisciplinary, Monthly, Multilanguage Journal Indexing in All Major Database & Metadata, Citation Generator

Cite This Article

"FORCED CONVECTION HEAT TRANSFER BY USING CLOCKWISE ARRANGEMENT OF BIPARTITION", International Journal of Emerging Technologies and Innovative Research (www.jetir.org | UGC and issn Approved), ISSN:2349-5162, Vol.12, Issue 5, page no. ppe906-e916, May-2025, Available at : http://www.jetir.org/papers/JETIR2505578.pdf

Publication Details

Published Paper ID: JETIR2505578
Registration ID: 562130
Published In: Volume 12 | Issue 5 | Year May-2025
DOI (Digital Object Identifier):
Page No: e906-e916
Country: Pandharpur, Maharashtra, India .
Area: Engineering
ISSN Number: 2349-5162
Publisher: IJ Publication


Preview This Article


Downlaod

Click here for Article Preview

Download PDF

Downloads

000110

Print This Page

Current Call For Paper

Jetir RMS