Review of Backstay Effect in Tall Buildings with Podiums and Basements

Abstract

This review paper comprehensively evaluates the phenomenon of Backstay Effect in tall buildings that include podium structures. The study includes fundamental mechanics, different modelling approaches, and the impact of the same in the structural behavior and seismic performance of the building. This section highlights the guidelines from the latest Indian standards along with well-known international references. It also explains how different parameters—such as podium height, diaphragm stiffness, and the overall tower configuration—can influence the structural response, providing a holistic understanding in optimizing design and safety improvements.

Key Words

Backstay Effect, Tall Buildings, Podium, Basements, Seismic Performance, Structural Modeling

Cite This Article

"Review of Backstay Effect in Tall Buildings with Podiums and Basements", International Journal of Emerging Technologies and Innovative Research (www.jetir.org), ISSN:2349-5162, Vol.12, Issue 11, page no.h432-h436, November-2025, Available :http://www.jetir.org/papers/JETIR2511704.pdf

ISSN


2349-5162 | Impact Factor 7.95 Calculate by Google Scholar

An International Scholarly Open Access Journal, Peer-Reviewed, Refereed Journal Impact Factor 7.95 Calculate by Google Scholar and Semantic Scholar | AI-Powered Research Tool, Multidisciplinary, Monthly, Multilanguage Journal Indexing in All Major Database & Metadata, Citation Generator

Cite This Article

"Review of Backstay Effect in Tall Buildings with Podiums and Basements", International Journal of Emerging Technologies and Innovative Research (www.jetir.org | UGC and issn Approved), ISSN:2349-5162, Vol.12, Issue 11, page no. pph432-h436, November-2025, Available at : http://www.jetir.org/papers/JETIR2511704.pdf

Publication Details

Published Paper ID: JETIR2511704
Registration ID: 572493
Published In: Volume 12 | Issue 11 | Year November-2025
DOI (Digital Object Identifier):
Page No: h432-h436
Country: Panvel, Maharashtra, India .
Area: Engineering
ISSN Number: 2349-5162
Publisher: IJ Publication


Preview This Article


Downlaod

Click here for Article Preview

Download PDF

Downloads

00029

Print This Page

Current Call For Paper

Jetir RMS