UGC Approved Journal no 63975(19)
New UGC Peer-Reviewed Rules

ISSN: 2349-5162 | ESTD Year : 2014
Volume 13 | Issue 11 | November 2026

JETIREXPLORE- Search Thousands of research papers



WhatsApp Contact
Click Here

Published in:

Volume 13 Issue 11
November-2026
eISSN: 2349-5162

UGC and ISSN approved 7.95 impact factor UGC Approved Journal no 63975

7.95 impact factor calculated by Google scholar

Unique Identifier

Published Paper ID:
JETIR2611004


Registration ID:
587511

Page Number

a19-a25

Share This Article


Jetir RMS

Title

EMG CONTROLLED ROBOTIC GLOVE FOR REHABILITATION

Abstract

Electromyography (EMG)-controlled robotic gloves offer a promising approach to assist hand movement during rehabilitation for individuals with impaired hand function. This project presents the design and implementation of a wearable robotic rehabilitation glove that uses surface EMG signals to detect muscle activity and initiate assisted finger movement. The proposed system comprises a two-channel EMG acquisition unit, an ESP32 microcontroller for signal processing and control, and five servo motors connected to a tendon-driven finger mechanism. The system processes the acquired EMG signals and compares them with an experimentally determined threshold to identify the user’s movement intention. Based on the detected muscle activity, the corresponding servo motor is activated to provide assisted finger movement. A lightweight glove with 3D-printed mechanical components integrates the sensing and actuation mechanisms into a wearable system. The project also includes a rehabilitation support application, RehabEase, for exercise and progress tracking. The developed prototype was evaluated through EMG signal testing, movement detection, servo response, and integrated finger-movement trials. The project aims to develop a low-cost, portable, and user-controlled rehabilitation system that can provide assisted hand movement while supporting regular rehabilitation exercises.

Key Words

EMG, robotic glove, hand rehabilitation, surface electromyography, signal processing, ESP32, servo motor, tendon-driven mechanism, assistive robotics.

Cite This Article

"EMG CONTROLLED ROBOTIC GLOVE FOR REHABILITATION", International Journal of Emerging Technologies and Innovative Research (www.jetir.org), ISSN:2349-5162, Vol.13, Issue 11, page no.a19-a25, November-2026, Available :http://www.jetir.org/papers/JETIR2611004.pdf

ISSN


2349-5162 | Impact Factor 7.95 Calculate by Google Scholar

An International Scholarly Open Access Journal, Peer-Reviewed, Refereed Journal Impact Factor 7.95 Calculate by Google Scholar and Semantic Scholar | AI-Powered Research Tool, Multidisciplinary, Monthly, Multilanguage Journal Indexing in All Major Database & Metadata, Citation Generator

Cite This Article

"EMG CONTROLLED ROBOTIC GLOVE FOR REHABILITATION", International Journal of Emerging Technologies and Innovative Research (www.jetir.org | UGC and issn Approved), ISSN:2349-5162, Vol.13, Issue 11, page no. ppa19-a25, November-2026, Available at : http://www.jetir.org/papers/JETIR2611004.pdf

Publication Details

Published Paper ID: JETIR2611004
Registration ID: 587511
Published In: Volume 13 | Issue 11 | Year November-2026
DOI (Digital Object Identifier):
Page No: a19-a25
Country: Bengaluru, Karnataka, India .
Area: Engineering
ISSN Number: 2349-5162
Publisher: IJ Publication


Preview This Article


Downlaod

Click here for Article Preview

Download PDF

Downloads

00012

Print This Page

Current Call For Paper

Jetir RMS