UGC Approved Journal no 63975(19)

ISSN: 2349-5162 | ESTD Year : 2014
Call for Paper
Volume 11 | Issue 4 | April 2024

JETIREXPLORE- Search Thousands of research papers



WhatsApp Contact
Click Here

Published in:

Volume 6 Issue 4
April-2019
eISSN: 2349-5162

UGC and ISSN approved 7.95 impact factor UGC Approved Journal no 63975

7.95 impact factor calculated by Google scholar

Unique Identifier

Published Paper ID:
JETIRBB06065


Registration ID:
204804

Page Number

306-313

Share This Article


Jetir RMS

Title

Investigation of Energy Saving Potential of Bulk Milk Chiller by Waste Heat Recovery

Abstract

In the age of globalisation energy saving has become significant. It has led to the increased energy and cost concern which encouraged an investigation of waste heat recovery from bulk milk chillers as a conservation alternative for reducing heat cost in diary industry. Milk chilling equipment used depends on the quantity of milk required to be handled. In coolers (BMC) ie. milk production practices the harvested milk is chilled from its initial temperature of 35 °C to 4 °C to arrest the bacterial growth and maintain the quality of milk. Milk chilling process by using BMC is energy intensive process. Hot water is used in dairy industry to clean all dairy processing equipment which is heated separately by using oil and gas as a fuel or electrical energy. This amount of energy required for water heating is saved by recovering and utilizing heat dissipated to atmosphere through condenser is recovered using a heat pump which saves the strain on the electric energy used to heat the water separately and eventually helped lessening the expenditure. An attempt has been made to design a tube in tube type heat exchanger capable to recover heat during the condensation process. Experimental investigations are done for water instead of milk which has nearly similar properties. In this paper energy saving potential in 150 litre capacity bulk milk cooler through heat recovery tube in tube type heat exchanger. It is revealed that there is considerable energy saving potential in bulk milk cooling systems. Significant improvements have been achieved and coefficient of performance (COP) of the system is about 2.73

Key Words

Cite This Article

"Investigation of Energy Saving Potential of Bulk Milk Chiller by Waste Heat Recovery", International Journal of Emerging Technologies and Innovative Research (www.jetir.org), ISSN:2349-5162, Vol.6, Issue 4, page no.306-313, April-2019, Available :http://www.jetir.org/papers/JETIRBB06065.pdf

ISSN


2349-5162 | Impact Factor 7.95 Calculate by Google Scholar

An International Scholarly Open Access Journal, Peer-Reviewed, Refereed Journal Impact Factor 7.95 Calculate by Google Scholar and Semantic Scholar | AI-Powered Research Tool, Multidisciplinary, Monthly, Multilanguage Journal Indexing in All Major Database & Metadata, Citation Generator

Cite This Article

"Investigation of Energy Saving Potential of Bulk Milk Chiller by Waste Heat Recovery", International Journal of Emerging Technologies and Innovative Research (www.jetir.org | UGC and issn Approved), ISSN:2349-5162, Vol.6, Issue 4, page no. pp306-313, April-2019, Available at : http://www.jetir.org/papers/JETIRBB06065.pdf

Publication Details

Published Paper ID: JETIRBB06065
Registration ID: 204804
Published In: Volume 6 | Issue 4 | Year April-2019
DOI (Digital Object Identifier):
Page No: 306-313
Country: 11111111, aaa, India .
Area: Engineering
ISSN Number: 2349-5162
Publisher: IJ Publication


Preview This Article


Downlaod

Click here for Article Preview

Download PDF

Downloads

0003017

Print This Page

Current Call For Paper

Jetir RMS