EFFECTS OF WIND LOAD ON RC BUILDINGS BY USING GUST FACTOR APPROACH

Abstract

The development of new architectural forms of buildings and flexible structural systems are vulnerable to wind action. For desirable performance of these building, we required better understanding of interaction between building and wind. The objective of this study is to understand provisions of international standards and compare them with Indian standard. Hence A wind load effects on RC buildings is conducted utilizing major codes and standards: IS 875 (Part-3):1987, IS 875 (Part-3):2015, ASCE 7-05. In this study also focuses on Indian code i.e. IS 875 (Part-3):2015 and point out the advantages over IS 875 (Part-3):1987.The present study deals with the buildings of different shape such as regular plans and irregular plans. IS: 875 (Part-3):2015 is the standard code of practice for design load of buildings and structures which was used to calculate the along wind load effect i.e. gust factor. To determine along wind load effect on different shapes of building using Indian standard, spread sheets are prepared. Further, all these shapes were analysed using finite element software package ETAB-2016. Each building is a 20 storied building with story height as 4m summing upto a total height of 80m. For, the purpose of analysis the plan area of regular shape like Square, Rectangular, Elliptical, Circular and Rectangle with two semicircle shapes kept same as well as the frame properties also kept equal.

Key Words

IS:875(Part-3):1987/2015, ASCE 7-05, Gust factor, Storey shear, Storey drift, Displacement.

Cite This Article

"EFFECTS OF WIND LOAD ON RC BUILDINGS BY USING GUST FACTOR APPROACH", International Journal of Emerging Technologies and Innovative Research (www.jetir.org), ISSN:2349-5162, Vol.6, Issue 4, page no.328-333, April-2019, Available :http://www.jetir.org/papers/JETIRBD06063.pdf

ISSN


2349-5162 | Impact Factor 7.95 Calculate by Google Scholar

An International Scholarly Open Access Journal, Peer-Reviewed, Refereed Journal Impact Factor 7.95 Calculate by Google Scholar and Semantic Scholar | AI-Powered Research Tool, Multidisciplinary, Monthly, Multilanguage Journal Indexing in All Major Database & Metadata, Citation Generator

Cite This Article

"EFFECTS OF WIND LOAD ON RC BUILDINGS BY USING GUST FACTOR APPROACH", International Journal of Emerging Technologies and Innovative Research (www.jetir.org | UGC and issn Approved), ISSN:2349-5162, Vol.6, Issue 4, page no. pp328-333, April-2019, Available at : http://www.jetir.org/papers/JETIRBD06063.pdf

Publication Details

Published Paper ID: JETIRBD06063
Registration ID: 205389
Published In: Volume 6 | Issue 4 | Year April-2019
DOI (Digital Object Identifier):
Page No: 328-333
Country: -, -, - .
Area: Engineering
ISSN Number: 2349-5162
Publisher: IJ Publication


Preview This Article


Downlaod

Click here for Article Preview

Download PDF

Downloads

0003054

Print This Page

Current Call For Paper

Jetir RMS