ANALYSIS AND DESIGN OF TWISTED BUILDING BY USING STAAD.PRO V8i

Abstract

Structural Analysis is a branch which involves in the determination of behaviour of structures in order to predict the responses of real structures such as buildings, bridges, trusses etc. Under the improvement of expected loading & external environment during the service life of structure. The results of analysis are used to verify the structure fitness for use. Computer software’s are also being used for the calculation of forces, bending moment, stress, strain &deformation or deflection for a complex structural system. The principle objective of this project is the Design and Analysis of a High Rise Twisted building (G+10) by using STAAD.Pro V8i software. STAAD.Pro is one of the leading software’s for the design of structures. In this project we had analysed the G+10 building for finding the shear forces, bending moments, deflections & reinforcement details for the structural components of building (such as Beams, columns & slabs) to develop the economic design. Finally we will make an attempt to define the economical section of G+10 twisted building using STAAD. Pro V8i Software tool.This project investigates challenges of designing buildings to accommodate challenging twisting architecture. The foremost challenge is to resist the torsion generated due to twisting geometry of the structure rising 10 stories, while rotating a total of 30°. The true twisting nature of the column posed a number of structural challenges that demanded innovative solutions. The horizontal component of the gravity load in the columns is resolved in the slabs then transferring it to core shear walls, which are the only consistently vertical structural elements in the building. The torsion caused by the remaining gravity load is resisted by a composite concrete shear wall and link beam system

Key Words

AnalysisandDesign,HighRise Twisted building,Residential Building, STAAD.Pro,StructuralEngineering..

Cite This Article

"ANALYSIS AND DESIGN OF TWISTED BUILDING BY USING STAAD.PRO V8i", International Journal of Emerging Technologies and Innovative Research (www.jetir.org), ISSN:2349-5162, Vol.6, Issue 4, page no.76-85, April-2019, Available :http://www.jetir.org/papers/JETIRBG06011.pdf

ISSN


2349-5162 | Impact Factor 7.95 Calculate by Google Scholar

An International Scholarly Open Access Journal, Peer-Reviewed, Refereed Journal Impact Factor 7.95 Calculate by Google Scholar and Semantic Scholar | AI-Powered Research Tool, Multidisciplinary, Monthly, Multilanguage Journal Indexing in All Major Database & Metadata, Citation Generator

Cite This Article

"ANALYSIS AND DESIGN OF TWISTED BUILDING BY USING STAAD.PRO V8i", International Journal of Emerging Technologies and Innovative Research (www.jetir.org | UGC and issn Approved), ISSN:2349-5162, Vol.6, Issue 4, page no. pp76-85, April-2019, Available at : http://www.jetir.org/papers/JETIRBG06011.pdf

Publication Details

Published Paper ID: JETIRBG06011
Registration ID: 207569
Published In: Volume 6 | Issue 4 | Year April-2019
DOI (Digital Object Identifier):
Page No: 76-85
Country: -, -, - .