UGC Approved Journal no 63975(19)

ISSN: 2349-5162 | ESTD Year : 2014
Call for Paper
Volume 11 | Issue 3 | March 2024

JETIREXPLORE- Search Thousands of research papers



WhatsApp Contact
Click Here

Published in:

Volume 5 Issue 8
August-2018
eISSN: 2349-5162

UGC and ISSN approved 7.95 impact factor UGC Approved Journal no 63975

7.95 impact factor calculated by Google scholar

Unique Identifier

Published Paper ID:
JETIRFF06010


Registration ID:
317190

Page Number

55-60

Share This Article


Jetir RMS

Title

A Review on Power Factor Improvement Using Induction Motor

Abstract

Capacitor banks are used to increase the power factor of a system. However, power factor adjustment is not required at all times since overcorrection may cause machine failure. The power factor enhancement of an induction motor utilizing a condenser controlled by a Programmable Logic Controller is described here (PLC). The energy savings measures are automatically accomplished by increasing the power factor of the induction motor. The value of a system that indicates how much power is borrowed from the power company for the system is known as the power factor. When the power factor falls below unity, an organization or business will need more current to provide the same quantity of power. Because of the voltage drop, line losses rise as the current increases, I2R. Because of their cheap cost, dependability, and robustness, induction motors are extensively utilized in industry. Induction motors have a relatively low power factor of approximately 0.33 with no load, however as the load increases, the power factor improves as we approach closer to full load. Low power factor is corrected using power factor correction, which reduces the phase mismatch between the voltage and current phasors. Controlling the power factor of a constantly changing load is challenging. Improved power factor is required to get as near to unity as possible without incurring penalties from electrical distributers. Because induction motors run with a trailing power factor, it is necessary to increase their power factor. Power factor is mostly operated closest to unity for systems to make them stable and the efficiency of the system as well as the apparatus capacity increases. Automatic power factor improvement techniques can be applied to industries, and power factor is mostly operated closest to unity for systems to make them stable and the efficiency of the system as well as the apparatus capacity increases. This is accomplished by reducing expenses via the usage of a microcontroller.

Key Words

Induction Motor (IM), Programmable Logic Controller (PLC), microcontroller, Zero Crossing Detector (ZCD)

Cite This Article

"A Review on Power Factor Improvement Using Induction Motor", International Journal of Emerging Technologies and Innovative Research (www.jetir.org), ISSN:2349-5162, Vol.5, Issue 8, page no.55-60, August-2018, Available :http://www.jetir.org/papers/JETIRFF06010.pdf

ISSN


2349-5162 | Impact Factor 7.95 Calculate by Google Scholar

An International Scholarly Open Access Journal, Peer-Reviewed, Refereed Journal Impact Factor 7.95 Calculate by Google Scholar and Semantic Scholar | AI-Powered Research Tool, Multidisciplinary, Monthly, Multilanguage Journal Indexing in All Major Database & Metadata, Citation Generator

Cite This Article

"A Review on Power Factor Improvement Using Induction Motor", International Journal of Emerging Technologies and Innovative Research (www.jetir.org | UGC and issn Approved), ISSN:2349-5162, Vol.5, Issue 8, page no. pp55-60, August-2018, Available at : http://www.jetir.org/papers/JETIRFF06010.pdf

Publication Details

Published Paper ID: JETIRFF06010
Registration ID: 317190
Published In: Volume 5 | Issue 8 | Year August-2018
DOI (Digital Object Identifier):
Page No: 55-60
Country: -, -, India .
Area: Engineering
ISSN Number: 2349-5162
Publisher: IJ Publication


Preview This Article


Downlaod

Click here for Article Preview

Download PDF

Downloads

000464

Print This Page

Current Call For Paper

Jetir RMS