UGC Approved Journal no 63975(19)

ISSN: 2349-5162 | ESTD Year : 2014
Call for Paper
Volume 11 | Issue 5 | May 2024

JETIREXPLORE- Search Thousands of research papers



WhatsApp Contact
Click Here

Published in:

Volume 5 Issue 7
July-2018
eISSN: 2349-5162

UGC and ISSN approved 7.95 impact factor UGC Approved Journal no 63975

7.95 impact factor calculated by Google scholar

Unique Identifier

Published Paper ID:
JETIR1807540


Registration ID:
185234

Page Number

546-553

Share This Article


Jetir RMS

Title

TIME HISTORY ANALYSIS OF AN ELEVATED WATER TANK FOR BHUJ EARTHQUAKE DATA & VALIDATION ON SHAKE TABLE

Abstract

Abstract: Elevated water tank is a water storage facility supported by a tower and constructed at an elevation to provide useful storage and pressure for a water distribution system. The height of the tower provides the pressure for the water supply system. During the high peak hours of the water system, the static potential reserved in the tank will be used to provide the pressure in the water pipes and helps the pumping systems by maintaining the necessary water pressure without increasing pumping capacity. They also present enough water pressure for firefighting when the pumping systems are not sufficient to provide large amount of water needed for fire extinguishing. In public water distribution system, Elevated water tanks are generally used being an important part of a lifeline system. Due to post earthquake functional needs, seismic safety of water tanks is of most important. Elevated water tanks also called as elevated service reservoirs (ESRs) typically consists of a container and a supporting tower. In major cities and also in rural areas elevated water tanks forms an Integral part of water supply system. The elevated water tanks must remain functional even after the earthquakes as water tanks are most essential to provide water for drinking purpose. These structures have large mass concentrated at the top of slender which have Supporting structure and hence these structures are especially vulnerable to horizontal forces due to earthquakes.

Key Words

keywords – water pressure, staad-pro, water tank

Cite This Article

"TIME HISTORY ANALYSIS OF AN ELEVATED WATER TANK FOR BHUJ EARTHQUAKE DATA & VALIDATION ON SHAKE TABLE", International Journal of Emerging Technologies and Innovative Research (www.jetir.org), ISSN:2349-5162, Vol.5, Issue 7, page no.546-553, July-2018, Available :http://www.jetir.org/papers/JETIR1807540.pdf

ISSN


2349-5162 | Impact Factor 7.95 Calculate by Google Scholar

An International Scholarly Open Access Journal, Peer-Reviewed, Refereed Journal Impact Factor 7.95 Calculate by Google Scholar and Semantic Scholar | AI-Powered Research Tool, Multidisciplinary, Monthly, Multilanguage Journal Indexing in All Major Database & Metadata, Citation Generator

Cite This Article

"TIME HISTORY ANALYSIS OF AN ELEVATED WATER TANK FOR BHUJ EARTHQUAKE DATA & VALIDATION ON SHAKE TABLE", International Journal of Emerging Technologies and Innovative Research (www.jetir.org | UGC and issn Approved), ISSN:2349-5162, Vol.5, Issue 7, page no. pp546-553, July-2018, Available at : http://www.jetir.org/papers/JETIR1807540.pdf

Publication Details

Published Paper ID: JETIR1807540
Registration ID: 185234
Published In: Volume 5 | Issue 7 | Year July-2018
DOI (Digital Object Identifier):
Page No: 546-553
Country: AHMADNAGAR, Maharashtra, India .
Area: Engineering
ISSN Number: 2349-5162
Publisher: IJ Publication


Preview This Article


Downlaod

Click here for Article Preview

Download PDF

Downloads

0002850

Print This Page

Current Call For Paper

Jetir RMS