Fiber Bragg Grating Sensor Based Device for the Measurement of Hand Grip Strength

Abstract

The quantification of human hand grip is important for understanding several important biomechanical aspects like neuromuscular system function, overall upper-limb strength, vertebral fracture and bone mass density (forearm, skeletal sites, spine, hip etc). This paper describes a novel Fiber Bragg Grating sensor based Hand Grip Device (FBGHGD) which can be used to quantify the human hand grip. Here, the strain dependent wavelength responses of FBGs are utilized to obtain the force applied by the human hand grip employing a novel mechanical package. The FBGHGD developed is calibrated using a Compression Testing Machine (CTM) to obtain the relation between the load/force exerted on FBGHGD and the shift in Bragg wavelength of the FBG sensor; this in turn is used to deduce the value of the force exerted in kilograms. Further, the FBGHGD is clinically tested against a commercial Jammer dynamometer with a series of standard test protocols and the obtained results are compared. The demonstrated FBGHGD is accurate and in comparison to dynamometer, it additionally provides real-time variations of the force exerted by hand grip which can be used to deduce several ergonomically vital parameters such as maximum grip force, stamina index, fatigue build-up etc., to aid in better understanding of skeletal muscle function, prediction of disability, incapacity and mortality.

Key Words

Fiber Braggs Grating, Hand grip force, Wrist force measurement, Grip force measurement, Musculoskeletal disorder.

Cite This Article

"Fiber Bragg Grating Sensor Based Device for the Measurement of Hand Grip Strength", International Journal of Emerging Technologies and Innovative Research (www.jetir.org), ISSN:2349-5162, Vol.6, Issue 6, page no.450-454, June 2019, Available :http://www.jetir.org/papers/JETIR1906Q63.pdf

ISSN


2349-5162 | Impact Factor 7.95 Calculate by Google Scholar

An International Scholarly Open Access Journal, Peer-Reviewed, Refereed Journal Impact Factor 7.95 Calculate by Google Scholar and Semantic Scholar | AI-Powered Research Tool, Multidisciplinary, Monthly, Multilanguage Journal Indexing in All Major Database & Metadata, Citation Generator

Cite This Article

"Fiber Bragg Grating Sensor Based Device for the Measurement of Hand Grip Strength", International Journal of Emerging Technologies and Innovative Research (www.jetir.org | UGC and issn Approved), ISSN:2349-5162, Vol.6, Issue 6, page no. pp450-454, June 2019, Available at : http://www.jetir.org/papers/JETIR1906Q63.pdf

Publication Details

Published Paper ID: JETIR1906Q63
Registration ID: 216900
Published In: Volume 6 | Issue 6 | Year June-2019
DOI (Digital Object Identifier):
Page No: 450-454
Country: Bangalore, karnataka, India .
Area: Engineering
ISSN Number: 2349-5162
Publisher: IJ Publication


Preview This Article


Downlaod

Click here for Article Preview

Download PDF

Downloads

0002819

Print This Page

Current Call For Paper

Jetir RMS