UGC Approved Journal no 63975(19)

ISSN: 2349-5162 | ESTD Year : 2014
Call for Paper
Volume 11 | Issue 10 | October 2024

JETIREXPLORE- Search Thousands of research papers



WhatsApp Contact
Click Here

Published in:

Volume 7 Issue 6
June-2020
eISSN: 2349-5162

UGC and ISSN approved 7.95 impact factor UGC Approved Journal no 63975

7.95 impact factor calculated by Google scholar

Unique Identifier

Published Paper ID:
JETIR2006563


Registration ID:
234343

Page Number

1584-1587

Share This Article


Jetir RMS

Title

Effect of Some Parameters on Cyclic Voltammetry of Selenium in Ethaline

Abstract

Cyclic voltammetry (CV) studies were used to investigate the interaction behavior of selenium from a solution containing selenium chloride (SeCl4) in choline chloride-ethylene glycol (EG) based ionic liquid called ethaline. The influences of various experimental conditions and some parameters on cyclic voltammetry have been investigated using a Hokudo Denko HAB-151 Potentiostat/Galvanostat, Tokyo, Japan, equipped with a potential sweeper. It is shown that the additions of 40 mL•L-1 acetonitrile and 0.05 mol•L-1 P2O5 cause significant changes in the shape and position of the voltammograms. The nature of cyclic voltammograms of Cu(II) has been changed dramatically in presence of the acetonitrile due to the strong interaction between metal ion and acetonitrile. The magnitude of the reduction current densities is significantly decreased on the addition of additives as compared with additive free IL. In this study, it was observed that an addition of acetonitrile as additive to solution containing Se(IV) with ethaline as supporting electrolyte caused an increase in the reduction current of Se(IV) by several factors and also with a slight cathodic shift in the reduction peak potential of Se(IV).

Key Words

Cyclic voltammetry, Selenium, Ethaline, Additives, Parameters.

Cite This Article

"Effect of Some Parameters on Cyclic Voltammetry of Selenium in Ethaline", International Journal of Emerging Technologies and Innovative Research (www.jetir.org), ISSN:2349-5162, Vol.7, Issue 6, page no.1584-1587, June 2020, Available :http://www.jetir.org/papers/JETIR2006563.pdf

ISSN


2349-5162 | Impact Factor 7.95 Calculate by Google Scholar

An International Scholarly Open Access Journal, Peer-Reviewed, Refereed Journal Impact Factor 7.95 Calculate by Google Scholar and Semantic Scholar | AI-Powered Research Tool, Multidisciplinary, Monthly, Multilanguage Journal Indexing in All Major Database & Metadata, Citation Generator

Cite This Article

"Effect of Some Parameters on Cyclic Voltammetry of Selenium in Ethaline", International Journal of Emerging Technologies and Innovative Research (www.jetir.org | UGC and issn Approved), ISSN:2349-5162, Vol.7, Issue 6, page no. pp1584-1587, June 2020, Available at : http://www.jetir.org/papers/JETIR2006563.pdf

Publication Details

Published Paper ID: JETIR2006563
Registration ID: 234343
Published In: Volume 7 | Issue 6 | Year June-2020
DOI (Digital Object Identifier):
Page No: 1584-1587
Country: Natore, Rajshahi, Bangladesh .
Area: Chemistry
ISSN Number: 2349-5162
Publisher: IJ Publication


Preview This Article


Downlaod

Click here for Article Preview

Download PDF

Downloads

0003275

Print This Page

Current Call For Paper

Jetir RMS