A NUMERICAL INVESTIGATION OF THERMODYNAMIC PERFORMANCE OF CASCADE REFRIGERATION SYSTEM OPERATED BY DIFFERENT REFRIGERANT PAIRS

Abstract

Due to increasing , global pollution in terms of air, water & soil, scientific community concentrating on development of new alternative refrigerants which are safe for nature & eco friendly. Many researchers of around the world have made part of accomplishments in the substitution of refrigerants, looking for the refrigerant option in low temperature circuit and high temperature circuit of cascade system with zero ODP & low GWP value. That is the reason I consider refrigerants in my research work with zero ozone depletion potential and low global warming potential. Natural refrigerants should be preferred for selecting refrigerants in cascade refrigeration system due to its environment friendly nature. Successful design of cascade vapour refrigeration system mainly depends upon the selection of refrigerants for both temperature circuits: high temperature circuit &low temperature circuit. The goal of my research work is to analyze two distinctive cascade vapour refrigeration system utilizing two refrigerant sets R41/R290 and R41/R600. Performances of cascade vapour refrigeration system using R41/R290 refrigerant pair & R41/R600 refrigerant pair are analyzed thermodynamically. A mathematical model used for this purpose.EES (ENGINEERING EQUATION SOLVER) software is used for mathematical modeling. Performances of cascade vapour refrigeration system in terms of COP, XTOTAL, WTOTAL & ηEx analyzed under various operating conditions like TEVA, TCON & TCASLTC .Result shows that the Coefficient of performance (COP) of refrigerant pair R41/R600 used in cascade vapour refrigeration system is higher compared to R41/R290 refrigerant pair operated at same working conditions.

Key Words

COP, Natural Refrigerants, Engineering Equation Solver, Mass Equilibrium

Cite This Article

"A NUMERICAL INVESTIGATION OF THERMODYNAMIC PERFORMANCE OF CASCADE REFRIGERATION SYSTEM OPERATED BY DIFFERENT REFRIGERANT PAIRS", International Journal of Emerging Technologies and Innovative Research (www.jetir.org), ISSN:2349-5162, Vol.8, Issue 3, page no.1826-1835, March-2021, Available :http://www.jetir.org/papers/JETIR2103224.pdf

ISSN


2349-5162 | Impact Factor 7.95 Calculate by Google Scholar

An International Scholarly Open Access Journal, Peer-Reviewed, Refereed Journal Impact Factor 7.95 Calculate by Google Scholar and Semantic Scholar | AI-Powered Research Tool, Multidisciplinary, Monthly, Multilanguage Journal Indexing in All Major Database & Metadata, Citation Generator

Cite This Article

"A NUMERICAL INVESTIGATION OF THERMODYNAMIC PERFORMANCE OF CASCADE REFRIGERATION SYSTEM OPERATED BY DIFFERENT REFRIGERANT PAIRS", International Journal of Emerging Technologies and Innovative Research (www.jetir.org | UGC and issn Approved), ISSN:2349-5162, Vol.8, Issue 3, page no. pp1826-1835, March-2021, Available at : http://www.jetir.org/papers/JETIR2103224.pdf

Publication Details

Published Paper ID: JETIR2103224
Registration ID: 306952
Published In: Volume 8 | Issue 3 | Year March-2021
DOI (Digital Object Identifier):
Page No: 1826-1835
Country: obaidullaganj raisen, m.p, India .
Area: Engineering
ISSN Number: 2349-5162
Publisher: IJ Publication


Preview This Article


Downlaod

Click here for Article Preview

Download PDF

Downloads

0003025

Print This Page

Current Call For Paper

Jetir RMS