Title

Evaluation of Simultaneous Dual-radioisotope SPECT Imaging Using 99m Tc and 131I

Abstract

The aim to study the effects of source concentration, acquisition & processing parameters on DSPECT image quality. The FWHM, differential uniformity, contrast, and SNR in the three transverse slices of the phantom was analyzed. When the phantom was filled with 20 mCi 99m Tc & 0.4 mCi 131I, were FWHM, differential uniformity and contrast are improved (P-values were statistically significant) with the higher SNR. On the other hand, HEGP collimator had better FWHM, differential uniformity and contrast with a suitable SNR. In the case of showed improvement of resolution in the case of 128 views rather than in 32 and 64 views. But in the case of Diff. Unif. % and the contrast we found that 64 NOP has the better values, which indicate the higher image quality. For SNR 32 NOP given the best values. In practice, approximately 60 views are adequate for most clinical studies. The scattering compensation is TEW subtraction method. Also, the study showed that, the reconstruction of DSPECT data were by (OSEM) iterative algorithm demonstrated quantitative accuracy comparable to FBP, FLASH-3D algorithm.

Key Words

Simultaneous radioisotope, 131I & 99m Tc imaging, Dual Single Photon Emission Computed Tomography (DSPECT), Imaging factors, image quality.

Cite This Article

"Evaluation of Simultaneous Dual-radioisotope SPECT Imaging Using 99m Tc and 131I", International Journal of Emerging Technologies and Innovative Research (www.jetir.org), ISSN:2349-5162, Vol.9, Issue 4, page no.d709-d729, April-2022, Available :http://www.jetir.org/papers/JETIR2204385.pdf

ISSN


2349-5162 | Impact Factor 7.95 Calculate by Google Scholar

An International Scholarly Open Access Journal, Peer-Reviewed, Refereed Journal Impact Factor 7.95 Calculate by Google Scholar and Semantic Scholar | AI-Powered Research Tool, Multidisciplinary, Monthly, Multilanguage Journal Indexing in All Major Database & Metadata, Citation Generator

Cite This Article

"Evaluation of Simultaneous Dual-radioisotope SPECT Imaging Using 99m Tc and 131I", International Journal of Emerging Technologies and Innovative Research (www.jetir.org | UGC and issn Approved), ISSN:2349-5162, Vol.9, Issue 4, page no. ppd709-d729, April-2022, Available at : http://www.jetir.org/papers/JETIR2204385.pdf

Publication Details

Published Paper ID: JETIR2204385
Registration ID: 400701
Published In: Volume 9 | Issue 4 | Year April-2022
DOI (Digital Object Identifier):
Page No: d709-d729
Country: Makkah, Makkah, Saudi Arabia .
Area: Medical Science
ISSN Number: 2349-5162
Publisher: IJ Publication


Preview This Article


Downlaod

Click here for Article Preview

Download PDF

Downloads

000372

Print This Page

Current Call For Paper

Jetir RMS