UGC Approved Journal no 63975(19)

ISSN: 2349-5162 | ESTD Year : 2014
Call for Paper
Volume 11 | Issue 4 | April 2024

JETIREXPLORE- Search Thousands of research papers



WhatsApp Contact
Click Here

Published in:

Volume 5 Issue 9
September-2018
eISSN: 2349-5162

UGC and ISSN approved 7.95 impact factor UGC Approved Journal no 63975

7.95 impact factor calculated by Google scholar

Unique Identifier

Published Paper ID:
JETIRE006069


Registration ID:
187742

Page Number

447-462

Share This Article


Jetir RMS

Title

DESIGN AND TRANSIENT OPERATION ASSESSMENT OF RESONANT FCLS IN BULK POWER SYSTEMS

Authors

Abstract

The increasing capacity of power systems and the continuing growth in interconnections within transmission networks to improve the reliability may cause the short-circuit fault current level of the equipment in the system, including the existing circuit breakers, to exceed their rated capacities. Therefore, the equipment must be either upgraded or replaced, which is costly and requires time-intensive procedures. Fault current-limiting techniques offer benefits to the system in such cases. Using passive elements, such as current-limiting reactors, is a well-known practice in power systems: however, they impact the power flow under normal operation, cause voltage drop, and might reduce the transient stability. Alternatively, resonant fault current limiters (RFCL) offer a dynamic solution based on proven technologies of current-limiting reactors and series capacitors. This paper presents a comprehensive framework to design RFCLs in bulk power systems. The presented approach uses a combination of mathematical analyses and numerical time-domain simulations to design the RFCL elements, and its effectiveness is assessed in test power systems.

Key Words

Cite This Article

"DESIGN AND TRANSIENT OPERATION ASSESSMENT OF RESONANT FCLS IN BULK POWER SYSTEMS", International Journal of Emerging Technologies and Innovative Research (www.jetir.org), ISSN:2349-5162, Vol.5, Issue 9, page no.447-462, September-2018, Available :http://www.jetir.org/papers/JETIRE006069.pdf

ISSN


2349-5162 | Impact Factor 7.95 Calculate by Google Scholar

An International Scholarly Open Access Journal, Peer-Reviewed, Refereed Journal Impact Factor 7.95 Calculate by Google Scholar and Semantic Scholar | AI-Powered Research Tool, Multidisciplinary, Monthly, Multilanguage Journal Indexing in All Major Database & Metadata, Citation Generator

Cite This Article

"DESIGN AND TRANSIENT OPERATION ASSESSMENT OF RESONANT FCLS IN BULK POWER SYSTEMS", International Journal of Emerging Technologies and Innovative Research (www.jetir.org | UGC and issn Approved), ISSN:2349-5162, Vol.5, Issue 9, page no. pp447-462, September-2018, Available at : http://www.jetir.org/papers/JETIRE006069.pdf

Publication Details

Published Paper ID: JETIRE006069
Registration ID: 187742
Published In: Volume 5 | Issue 9 | Year September-2018
DOI (Digital Object Identifier):
Page No: 447-462
Country: Chennai, Tamil Nadu, India .
Area: Engineering
ISSN Number: 2349-5162
Publisher: IJ Publication


Preview This Article


Downlaod

Click here for Article Preview

Download PDF

Downloads

0003092

Print This Page

Current Call For Paper

Jetir RMS